Key type and Dimension |
Operating Characteristics |
|
Key plug in force |
147.N(1,500gf) |
key pull out force |
29.42N(3,000gf) |
Pretravel |
6 +-3mm |
Total travel |
(28mm) |
Force required to have positive |
58.84N(6,000gf) |
Positive opening travel |
10mm | |
|
|
Designation |
Signal |
Description |
Type |
EC-93 |
Safety switch |
Type of contact blocks fitted |
B |
2B(2NC) |
C |
1A1B(NO-NC) |
Conduit entries
|
PG |
PG 13.5XP1.5 |
PT |
PT1/2X14UNC |
Actuating keys |
None |
None |
01 |
Horizontal |
02 |
90 Vertical |
03 |
Adjustable |
Ratings
Rated voltage
|
Noninductive Load (A)
|
nductive Load (A) |
Resistance Load
|
Lamp Load
|
Inductive Load
|
Motor Load
|
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
125VAC 250VAC 500VAC |
10 10 10 |
3 2 1.5 |
1.5 1 0.8 |
10 10 3 |
5 3 1.5 |
2.5 1.5 0.8 |
8VDC 14VDC 30VDC 125VDC 250VDC
|
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
3 3 3 0.2 0.1 |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
6 6 4 0.2 0.1 |
Characteristics
Rating |
3A 240VAC (A300) |
Operation speed |
0.1m ~0.5m/s |
Operating frequency |
30 operations/minute |
Contact resistance |
25m max. (initial). |
IInsulation resistance |
100m min. (at 500VDC) |
Rated insulation voltage(UI) |
400V |
Dielectric strength |
AC2500V/Umip 4KV |
Vibration |
10 to 55Hz, 0.65mm double amplitude |
Shock |
Mechanical: Approx. 1000m/s2(Approx. 100G'S) Electrical: Approx. 300m/s2(Approx. 30G'S) |
Ambient temperature |
-30~+70 |
Ambient Humidity |
< 95% RH |
Life |
Mechanical: 10,000,000 operations/min. Electrical: 150,000 operations/min. |
Degree of protection |
IP65(EN60947-5-1) |
Short-circuit protective device |
10A fuse |
Weight |
Approx. 76g |
|